Kinetics Database Resources
Simple Reaction Search
Search Reaction Database
Search Bibliographic Database
Set Unit Preferences
Feedback
Rate Our Products and Services
Help
Other Databases
NIST Standard Reference Data Program
NIST Chemistry Web Book
NDRL-NIST Solution Kinetics Database
NIST Computational Chemistry Comparison and Benchmark Database
The NIST Reference on Constants, Units, and Uncertainty
More...
Administrative Links
NIST home page
MML home page
Chemical and Biochemical Reference Data Division
MML home page
Chemical and Biochemical Reference Data Division
|
Author(s):
Swihart, M.T.; Carr, R.W.
Title:
Pulsed laser powered homogeneous pyrolysis for reaction kinetics studies: probe laser measurement of reaction time and temperature
Journal:
Int. J. Chem. Kinet.
Volume:
28
Page(s):
817 - 828
Year:
1996
Reference type:
Journal article
Squib:
1996SWI/CAR817-828
Reaction:
CH3COOC2H5 → CH3C(O)OH + C2H4
Reaction order:
1
Temperature:
960 - 1160
K
Pressure: 0.13 bar
Rate expression:
2.5x1012 [s-1] e-200832 [±4602 J/mole]/RT
Uncertainty:
10.0
Category: Experiment
Data type:
Relative value normalized by a reference value
Experimental procedure:
Other
Excitation technique:
Thermal
Analytical technique:
Gas chromatography
Comments:
Experiments were carried out with the pulsed laser powered homogeneous pyrolysis technique.
The stated value was derived with the comparative rate technique relative to the reaction
iso-C3H7Cl -> CH3CH=CH2 + HCl
using log k(iso-C3H7Cl -> CH3CH=CH2 + HCl)/s-1 = 13.6 - (51.1 kcal mol-1/2.3RT)
The authors do not report the exact temperature range of their experiments. The stated temperature range was derived from the data shown in Figure 7 of the paper and is approximate.
View full bibliographic record.
Rate constant values calculated from the Arrhenius expression:
| T (K) | k(T) [s-1] |
| 960 |
2.96E1 |
| 975 |
4.35E1 |
| 1000 |
8.09E1 |
| 1025 |
1.46E2 |
| 1050 |
2.55E2 |
| 1075 |
4.36E2 |
| 1100 |
7.27E2 |
| 1125 |
1.18E3 |
| 1150 |
1.89E3 |
| 1160 |
2.26E3 |
|